top of page

E.O Gas Test

E.O Gas Test is an ethylene oxide sterilization process indicator designed to indicate, through a visible color change, when the device has been exposed to an ethylene oxide sterilization process. The test designed to monitor all critical parameters of Ethylene Oxide sterilization (time, temperature, gas concentration, and humidity). The test can be used in every pouch or pack and will assure ethylene oxide gas penetration into the packs with a uniform color change from blue to light green. This product is designed for use in ethylene oxide sterilizers. 

  • Water-based and non-toxic chemical indicator

  • It is easy to read and interpret

  • Compatible with ISO 11140-1

  • Customer oriented designs are possible

EO-GAS-TEST.jpg
H2O2 Plasma Test

H2O2 Plasma Test

H2O2 Plasma Test is designed to be used at low-temperature hydrogen peroxide gas plasma sterilizers. The test can be used in every pouch or pack and will assure sufficient hydrogen peroxide gas penetration into the packs with a uniform color change from purple to blue.

  • Water-based and non-toxic chemical indicator

  • It is easy to read and interpret

  • Compatible with ISO 11140-1

  • Customer oriented designs are possible

H2O- Test.jpg

Formaldehyde Test

Formaldehyde Test is designed to be used at low-temperature formaldehyde gas sterilizers. The test can be used in every pouch or pack and will assure sufficient formaldehyde gas penetration into the packs with a uniform color change from claret red to green.

  • Water-based and non-toxic chemical indicator

  • It is easy to read and interpret

  • Compatible with ISO 11140-1

  • Customer oriented designs are possible

Formaldehyde Test
Formaldehyde-Test.jpg
Ultrasonic Washer Test

Ultrasonic Washer Test

Ultrasonic Washer Tests consist of a clear vial filled with reactive green-colored solution and glass beads. The device monitors the cavitation capacity of the ultrasonic washer. When functioning correctly, the vibration of glass pearls will trigger a color change to a yellow color.  Ultrasonic Washer Tests do not require a special holder to be used. The washer test should be checked daily and weekly than the results should be recorded.

  • It is easy to read and interpret

  • Compatible with ISO 15883-5

 

When do I use the Ultrasonic Washer Test?

Ultrasonic Washer Tests should be used in each ultrasonic cycle. The Ultrasonic Washing machine should also be checked at least once a week with recorded results. This will detect any deterioration in the performance of the cleaner and assist in preventing ineffective washing.

washer-dist.jpg

 Washer Disinfector Cleaning Efficiency Test

Washer Disinfector Cleaning Efficiency Test

Washer Disinfector Cleaning Efficiency Test enables you to verify the cleaning efficacy of washer-disinfectors during routine operation check. The routine use of this test will help ensure that your washer is performing at a consistent level, enhancing the routine visual inspection of instruments. If unfavorable results do occur, users must check quality/ quantity of detergent, cleaning time, temperature as well as the general condition of the washer.

  • Ready-to-use (single-use product)

  • The test provides efficient and reliable results

  • Transparent cover to enable visual check

  • Test made from steel and it has a plastic container that enables the user to hang the test on the washer-disinfectors

  • The coating on the test simulates human blood

  • It is easy to read and interpret

Washer Disinfector Cleaning
washer-disinfector.jpg
washer-disinfector-1.jpg
washer-disinfector-2.jpg

New Test Soil and Stainless Steel PCD

New Test Soil

New Test Soil is used for daily control and validation of the washer-disinfectors. It is also made from steel and has a coating that simulates human blood. When it is used with Stainless Steel PCD which is like a steel box with holes and a spring, they simulate a joint of medical equipment.

  • Ready-to-use (single-use product)

  • The test provides efficient and reliable results

  • Test made from steel

  • The coating on the test simulates human blood

  • It is easy to read and interpret

new-test-2.jpg
new-test-1.jpg

Washer Disinfector Efficiency and Ultrasonic Efficiency Control Test

Designed for monitoring washer and ultrasonic washer device efficiency. Both can be used Stainless Steel Frame as their holder.

  • Ready-to-use (single-use product)

  • The test provides efficient and reliable results

  • Transparent cover to enable visual check

  • Both can be used with the holder

  • Compatible with ISO 15883-5

It is easy to read and interpret

Washer Disinfector Efficiency
dis-infector-efficiency-1.jpg
dis-infector-efficiency-2.jpg
dis-infector-efficiency-3.jpg

Washer Tag with Washer Disinfector Cleaning Efficiency Test Soil

Washer Tags are designed to be used as a tag to identify if the tray is washed or not.

  • Ready-to-use (single-use product)

  • The test provides efficient and reliable results

  • It is easy to read and interpret

  • Patented design

Washer Tag
washer-tag-1.jpg
washer-tag-2.jpg

Cannulacheck

Cannula Check

Cannulacheck can be considered as a kind of simulation which performs like dried blood on long stainless steel placed inside hollow closed metal as same as hollow instruments of minimally invasive surgery.  With its closed stainless-steel system, the cleaning performance of washers can be tested whether their performance enough to reach inside of hollow instruments.

After the washing cycle, the test must be visually clean. If not; the washing cycle must be repeated.

  • Ready-to-use

  • Test single-use product and the tube is reusable

  • The test provides efficient and reliable results

  • It is easy to read and interpret

canula-1.jpg
canula-2.jpg

Individual Bowie&Dick Test

Individual Bowie-Dick Test Sheets are designed for use in the towel-pack version of the Bowie & Dick test. The high sensitivity ink of the product and easy interpretation of color changes guarantee the earliest possible warning of impending problems in pre-vacuum sterilizers. A Bowie-Dick Test Sheet should be placed within a stack of surgical towels that are assembled according to AAMI guidelines.

  • Individual Bowie-Dick tests make testing steam penetration and air removal, as well as detecting air leaks, more convenient and cost-effective

  • Water-based and non-toxic chemical indicator

  • Indicator pattern is easy to read and interpret

  • The indicator sheet contains fields to be filled out and it can be kept as a permanent record for traceability purposes

  • Compatible with ISO 11140-4 (Class 2 + 4)

Customer oriented designs are possible

​Individual Bowie&Dick Test
ind-bowie-dick-test.jpg

Seal Test

Seal Test

Seal Test is used to control the sealing machine whether if it meets the sealing standards or not. Seal test; visibly show the sealing machine results and quality so that the sealing problems can be found quickly and can be used to ensure the sealing parameters, requirements, and the quality.

  • It is easy to read and interpret

seal-test.jpg